18
5.2.3. PC.2P – Double click function programming
Activating this function causes activation of the chosen channel only after second pressing the button in the
remote what makes the probability of accidental triggering of the channel smaller. Second pressing of the button must
take place in the time to 3 seconds after first pressing of the button.
To switch on the function of double click it is necessary to (Fig. 17):
in main menu with NEXT button choose PC option and press OK/ESC button of the receiver;
the display shows 'PC.C1';
while in PC option with NEXT button choose PC.2P and OK/ESC button;
the display shows '2P._x' where 'x' is a channel number which is configured, if the channel is to have double click
function switched on, with NEXT button set in front of the channel number "C" ('2P.Cx'), if the channel is not to
have double click function switched on, set "_" ('2P._x'); the change of edited channel number is done by longer
pressing of NEXT button.
At any time it is possible to withdraw from the edition by pressing and holding OK./ESC button of the receiver.
This function concerns only radio receiver control. It does not concern control from the level of CloudFlex and
V-remote applications.
Fig. 17
Double click programming, PC.2P function in main menu of the receiver.