14
5.1.6. Bc option – individual blockade of remote assigning function
There are three possible settings of the blockade (Fig.13):
bc.on – the remote doesn’t have the possibility to take part in remote assigning process;
bc.bA – admin blockade – all the remotes assigned remotely with the use of that remote have ‘bc.on’ function on
automatically (they cannot be used to assign next remote controls remotely);
bc.oF – no blockade – the remote can take part in remote assigning process of new remotes.
Default setting is 'bc.oF' option.
To change the settings of the blockade of remote assigning it is necessary to:
in remote edition mode (PP) with NEXT button set bc option and press OK/ESC button of the receiver;
with NEXT button set the necessary value of the parameter and press OK/ESC button of the receiver.
At any time it is possible to withdraw from the edition by pressing and holding OK./ESC button of the receiver.
Blockade function discussed here is an individual function for a particular remote. To set the blockade to all
assigned remotes it is necessary to use global blockade function of remote assigning on the level of main
menu.
Fig. 13
Activating the individual blockade of remote assigning function of remote controls within the radio range
of the receiver , bc function in the PP submenu of the receiver.