![Dräger X-plore 8000 Instructions For Use Manual Download Page 21](http://html.mh-extra.com/html/drager/x-plore-8000/x-plore-8000_instructions-for-use-manual_2526856021.webp)
Maintenance
Dräger X-plore 8000
21
4.2
Alarms
The type of alarm is indicated optically by
red
flashing of the
corresponding indicator. In addition, an acoustic alarm and the
vibration alarm are triggered.
5
Maintenance
5.1
Maintenance intervals
5.2
Cleaning and disinfecting
5.2.1
Clean and disinfect the device
1. Dismantling the device:
a. Separate breathing hose, facepiece and fan unit from
each other.
b. Disconnect the carrying system from the fan unit.
c. If available, dismantle any accessories (e.g. hose and
device sleeves).
d. Dismantle splash guard cover and filter (see section
5.3.4 on page 22).
2. Clean the facepiece according to the appropriate Instruc-
tions for Use.
3. Cleaning the breathing hose and carrying system:
a. Clean all parts with lukewarm water and Sekusept
®
Cleaner
1)
with a soft cloth (max. temperature: 30 °C;
concentration depending on the degree of contamina-
tion: 0.5 - 1 %).
b. Rinse all parts thoroughly under running water.
c. Prepare a disinfectant bath of water and
Incidin
®
Rapid
2)
(temperature: 30 °C; concentration:
1.5 %).
d. Place all parts to be disinfected into the disinfectant
bath (duration: 15 minutes).
e. Rinse all parts thoroughly under running water.
f.
Allow all parts to air-dry or dry them in the drying cabi-
net (temperature: 60 °C). Keep away from direct sun-
light.
4. Clean and disinfect fan unit and splash guard cover using
Incides
®
N disinfectant cloths
1)
.
In cases of strong contamination, the fan unit can be rinsed un-
der running water as follows.
1. Make sure the rechargeable battery remains inserted. Wa-
ter must not enter the battery compartment.
2. Close suction inlet and tube connection with protective
caps (available as accessories).
5.3
Maintenance work
5.3.1
Visual inspection
Check all parts thoroughly and replace damaged parts if nec-
essary. Check particularly the filter sealing surface on the fan
unit for damage (e.g. scratches) or contamination.
Fault
Cause
Remedy
A segment of the
battery status indi-
cator is flashing
red
.
The residual run-
time of the re-
chargeable battery
is almost exhaust-
ed (< 10 minutes).
Recharge the bat-
tery or replace with
fully charged bat-
tery (see section
5.3.3 on page 22).
A segment of the
particle filter resid-
ual capacity indica-
tor is flashing
red
.
The particle filter
residual capacity is
almost exhausted
(< 10 %).
Change particle or
combination filter
(see section 5.3.4
on page 22).
A segment of the
flow rate indicator
is flashing
red
.
Faulty breathing air
supply during oper-
ation (e.g. caused
by missing hose or
filter).
Verify device func-
tion and prepare
again for use (see
section 3.2 on
page 19).
One segment at a
time is flashing
red
.
General system er-
ror
Device must be
checked by Dräger
Service.
Work to do
Before use
Af
te
r us
e
Annually
Ever
y 2 year
s
As n
e
ces
sar
y
Clean and disinfect the de-
vice
X
X
1)
1) for gas-tight packed devices, otherwise every 6 months
Visual inspection
X
X
1)
Check battery capacity
X
Replace rechargeable battery
X
Charge rechargeable battery
X
Replace filter
X
Check flow rate and warning
devices
X
Replace O-ring at plug-in or
bayonet-type hose connector
X
X
CAUTION
Potential damage to components!
Only use the prescribed processes and the cleaning
and disinfection agents specified for cleaning and disin-
fecting. Other agents, methods, dosages and contact
times may damage the components.
Health hazard!
The undiluted agents are damaging to health if they
come into direct contact with the eyes or skin. Wear
safety goggles and protective gloves when working
with these agents.
1) Sekusept
®
and Incides
®
are registered trademarks of Ecolab
Deutschland GmbH.
2) Incidin
®
is a registered trademark of Ecolab USA Inc.
!