Problem
Thermocouple not warm
enough yet
Keep the ignition button pressed longer.
Thermocouple is not in the
pilot flame
Position the thermocouple correctly in the flame (*).
Soot deposit on ther-
mocouple
Clean the thermocouple with a cloth.
Thermocouple faulty
Replace the thermocouple (*).
No spark
Spark but no ignition
When ignition button is released, pilot flame goes out
Main burner does not ignite
Whistling between high and low setting
Disrupted flame effect
Gas smell
Smell of combustion gases in room
Appliance goes out
Remote control does not work
possible cause
possible solution
(*) = have installer carry out this action
Electromagnetic valve faulty
Replace the control block (*).
Blocked pipes or nozzles
Blow through the parts and clean them (*).
Burr on nozzle
Remove the burr (*).
Dirty burner
Clean the burner, check the placement of the logs,
remove any coal from the burner openings (*).
Gas leak
Close the main valve, find the gas leak and repair the leak
(*).
Blocked smoke exhaust
duct or air supply ducts
Check the pipes and clean them (*).
Appliance is leaking air
Check the door seals and appliance joints (*).
Dust on combustion cham-
ber
Clean the combustion chamber.
Empty batteries
Replace the batteries.
Wiring to gas block
Trace any bad contact point and repair it.
Faulty transmitter or
receiver
Replace the remote control.
Subject to change because of technical improvements
29
Summary of Contents for ASTRO4GA - P
Page 23: ...Wijzigingen op grond van technische verbeteringen voorbehouden 23 ASTRO4GA P WB...
Page 52: ...Appendix 2 Dimensions ASTRO4GA P P 22 Subject to change because of technical improvements...
Page 53: ...ASTRO4GA P WB Subject to change because of technical improvements 23...
Page 63: ......
Page 86: ...ASTRO4GA P WB 24 Sous r serve de modifications dues des am liorations techniques...
Page 118: ...Anlage 2 Abmessungen ASTRO4GA P P 24 nderungen aufgrund technischer Verbesserungen vorbehalten...
Page 119: ...ASTRO4GA P WB nderungen aufgrund technischer Verbesserungen vorbehalten 25...
Page 152: ...ASTRO4GA P WB 24 Dovre se reserva el derecho de realizar cambios por razones t cnicas...