Troubleshooting
SECTION 06 Troubleshooting
36/54
Reassembly:
□ Fit the two screws to the new ink management module.
□ Bring up the new ink management module in order to connect the venting hose and
the CPU ribbon cable.
□ Insert the two screws into the corresponding slots and the two bottom mounts in their
brackets.
□ Tighten the two mounting screws.
□ Clean the seal mating surface on the multi-way hydraulic connector, remove the old
O-rings and fit five new O-rings. Tighten the three screws. Place the connector in the
console.
CAUTION:
the hoses must not obstruct the fan.
□ Pass the motor control wires back through the grommet and reconnect the connector
to the CPU board.
□ Reassemble the cartridge support plate.
Testing:
□ Restart the printer.
□ Autocalibration is required (see procedure).