Troubleshooting
SECTION 06 Troubleshooting
27/54
Replacing the nozzle plate.
■ Tools:
1.5 mm Allen wrench; 2.5 mm flat-bladed screwdriver.
CAUTION:
Turn off the printer and unplug it from its AC outlet.
Residual ink may pour out, take appropriate precautions.
Perform this operation in a dust-free environment.
■ Disassembly:
□ Open the head cover. Disassemble the resonator protective cover. Disconnect the
resonator wires.
□ Unscrew the two screws holding the modulator assembly and remove it. Take care
with the seals (two O-rings).
□ Unscrew the two screws from the nozzle plate and remove it. Take care with the seal
(one O-ring).
■ Reassembly:
□ Clean the nozzle plate seal mating surface with additive, remove the old O-ring and fit
a new one. Reassemble the nozzle plate on the modulator assembly.
□ Clean the modulator assembly seal mating surface with additive, remove the old O-
rings and fit two new O-rings in their locations on the head.
□ Place the new modulator assembly in position then tighten the two mounting screws.
□ Reconnect the resonator power supply cord and reinstall the protective cover.
■ Testing:
□ Start the printer.
□ A "stability check" is required. Gutter adjustment may be necessary.