4.3 Entrapment Protection Wiring
Type of wiring to be used on ALL external devices:
A)
Type
CL2
,
CL2P
,
CL2R
, or
CL2X
.
B)
Other cable with
equivalent
or
better
electrical,
mechanical, and flammability ratings.
Monitored CLOSE Photo Sensor
Monitored OPEN Photo Sensor
Normally Closed (N.C.)
Normally Closed (N.C.)
OPEN Beam
CLOSE Beam
IMPORTANT:
Photo sensors must use
Normally Closed (NC)
contacts with the beam set for light operate (relay activated when
beam is not obstructed). Some manufacturer’s photo sensor
contacts are labeled as
Normally Open (NO)
but their relay
functions the same way as described above. See specific
manufacturer’s wiring manual for more information about their
specific relay function.
Entrapment protection is
RECOMMENDED
for this area.
If the distance between an
entrapment or obstruction
exists less than 16” from
the open gate, then
entrapment protection is
REQUIRED
for this area.
Note:
Only 1 monitored device
can be connected to each input.
An
OPTIONAL
Expansion Kit
(sold separately) will allow
connection for additional devices.
1
2
3
4
5
6
OPEN Beam STOP (Switch 1)
CLOSE Beam REVERSE (Switch 2)
OPEN Edge/Beam REVERSE (Switch 3)
CLOSE Edge/Beam REVERSE (Switch 4)
Ground (Common)
Ground (Common)
OB
CB
OE
CE
G
G
1
2
3
4
5
6
OB
CB
OE
CE
G
G
Sensor LEDs
1
ON
2 3 4
1
ON
2
3 4
UL 325 DIP-Switches
UL 325 DIP-Switches
DIP-switches
MUST
be turned
ON
for each device wired to terminal.
DIP-switches 1 & 2
MUST
be turned
ON
.
Sensor LEDs Note:
LED ON:
Connected device has been activated.
LED remains off during normal operation.
LED Flashing:
Connected device is in fault.
Wiring to device is bad.
External Entrapment Protection Devices:
In addition to the inherent reversing sensor system, this operator has a UL 325 terminal for the connection of
photo sensors
-Type B1 and/or
reversing edges
-Type B2 entrapment protection required by UL 325 standards.
Entrapment Protection must be provided for the gate system
where the risk of entrapment or obstruction exists. The operator will NOT run without one or more monitored type B1 or B2 external
entrapment protection devices installed in EACH entrapment area.
Install these devices where the risk of entrapment or a safety hazard
exists. Installations can vary.
(2) Two 115 VAC
Convenience Outlets
1
2
5
6
11
13A
13B
13E
25
16
17
L1
L2
L3
B-
B+
M
od
e
EPM
0 0
0
SCM se
ries
bas
ic I
/O c
ontro
l
PUS
H
TO
OPER
AT
E
tec
hn
ici
an
us
e o
nly
MI
N
MA
X