6555-065-A-12-18
2
5
1
2
3
P9
1
2
3
TIME
DELAY
EXIT
LOOP
LMT
LMT
REVERSE
LOOP
REV SENSE
OPEN
REV SENSE
CLOSE
1
ON
2
3
4
1
ON
2
3
4
5
6
7
8
NC
NO
P8
P7
P6
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
4404-018
OB
CB
OE
CE
G
G
1
ON
1477-010
SW1
2 3 4
FIRE
4.3 Entrapment Protection Wiring Continued
UL 325 DIP-Switches
DIP-switches
MUST
be turned
ON
for each device wired to terminal.
Monitored OPEN/CLOSE Reversing Edge
WIRELESS
Multiple Reversing Edge Configuration
OPTIONAL Wireless Note:
Refer to the instruction
sheet that comes with the receiver/transmitter for
more specific wiring and mounting instructions.
24 VAC
Wireless Receiver
for Reversing Edge
24 VAC
Power
Normally Closed (N.C.)
Com
To Com
To Open/Close
Edge
OPEN/CLOSE
2-Wire End-of-Line Edge
Hardwiring arranged so that
the communication between
the sensor and the gate
operator is
NOT
subjected
to mechanical damage.
Potential
Entrapment
Area
Main Terminal
#3 Note:
Exceeding the
mA of power
from this
terminal may
cause the circuit
board
transformer to
overheat,
causing
intermittent
problems.
Main Terminal
If the distance between an
entrapment or obstruction
exists less than 16” from
the open gate, then
entrapment protection is
REQUIRED
for this area.
Receiver
MUST
monitor for the
presence of the
transmitter.
Type of wiring to be used on ALL external devices:
A)
Type
CL2
,
CL2P
,
CL2R
, or
CL2X
.
B)
Other cable with
equivalent
or
better
electrical, mechanical,
and flammability ratings.
4-Wire
In-Line Edge
4-Wire
In-Line Edge
2-Wire
End-of-Line Edge
Monitored Edge
Transmitter
HARDWIRED
Multiple Reversing Edge Configuration
Wiring Multiple Reversing Edges
(Add as many “4-wire” In-Line edges as needed)
Reversing Edges are wired in series
2-Wire
End-of-Line Edge
4-Wire
In-Line Edge
4-Wire
In-Line
Edge
4-Wire
In-Line
Edge
4-Wire
In-Line Edge
Black to Black. White to White.
To Wireless Edge Transmitter
OR
Operator Aux Terminals 9 & 10
Entrapment protection is
RECOMMENDED
for this area.
Entrapment Protection must be provided for the gate
system where the risk of entrapment or obstruction
exists. The operator will not run without one or more
monitored type B1 or B2 entrapment protection
devices in EACH entrapment area.
2-Wire
End-of-Line
Edge
Wiring to Operator
OB
CB
OE
CE
G
G
1
ON
1477-010
SW1
2 3 4
LED Notes:
LED OFF:
appropriate
device is
connected.
LED ON:
device has
been
activated.
Flashing LED:
Device NOT
connected.
Not
appropriate
device.
1
2
3
4
5
6