6555-065-A-12-18
22
4.1 Main Terminal Description
SECTION 4 - WIRING
NC
NO
P7
OB
CB
OE
CE
G
G
1477-010
4404
#4
#2
#5
#6
#7
#
8
#9
20
1919
1818
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Current Sensor
Current Sensor
Earth Ground
Motor Hot
Motor Neutral
Dry Relay Contact
Entrapment Alarm
Alarm Reset
Full Open
Dry Relay Contact
24 VAC - 250 mA max.
Full Open
DO NOT USE
Standard Reverse OR Stop
Low Voltage Common
Low Voltage Common
DANGER
HIGH VOL
TAGE!
Used in conjunction with the
circuit board inherent
reversing sensors. See page
20 for further information.
Main Terminal Input LEDs Note:
The LED
that is to the left of the main terminal wiring
input will light when that terminal input gets
activated.
Main T
erminal Input LEDs
(See note below)
1
2
3
P9
1
2
3
3-Button Station Stop
(3-Button Station jumper on Pins 1 & 2)
Low Voltage Common
3-Button Station Full Open
3-Button Station Close
P9
P9
Gate Tracker
Terminal
See page 23
1
ON
2
3
4
5
6
7
8
•
SW 1, switch 3 is
ON
, terminal #4 functions as a normal
FULL
open input. (Normal Setting).
Single operator use ONLY
.
•
SW 1, switch 3 is
OFF
, input to terminal #4
becomes the output from a plug-in loop
detector installed in the
EXIT loop port
of the
circuit board.
Main Terminal #3 Note:
Exceeding 250 mA of power from this terminal
may cause the circuit board transformer to
overheat, causing intermittent problems.
4
6
9
11 12
Operation of relay is dependent on
setting of SW 1, switches 4 and 5.
See page 17 and 18 for DIP-switch
function descriptions.
Relay contacts can be set for
Normally Open (NO) or
Normally Closed (NC) operation.
Contact rating is 1 amp maximum
at 24-volts DC.
1
ON
2
3
4
5
6
7
8
NO
NC
16 17
G
3-Button
Station
Jumper
Relay
OP
EN
ST
OP
CLOS
E
Factory
Setting
IMPORTANT:
Leave 3-button control
station jumper pins on 2 & 3 when
NOT
wiring a 3-button control station to control
board otherwise operator will
NOT
fuction.
Jumper Pins 1 & 2
ONLY
when
using a 4-wire control station
to
enable STOP
terminal #9.
3-Button Control Station Jumper
3
2
1
3
2
1
#5
UL 325
Terminal
See pages 24 & 25
FIRE
1
ON
2
3
4
5
6
7
8
This input ONLY fuctions when gate is
fully opened
or in
the
closing cycle
.
When gate is closing: An input to terminal #6 will stop and
reverse
and the gate to the full open position.
Note:
If the auto-close timer is
ON
, when gate reaches the
open position, timer will time out and close the
gate.
Shadow loop connection if desired, see page 26.
DO NOT
use ON setting.
Switch 7
must be
OFF
.