SECTION 3 - ADJUSTMENTS
3.1 Circuit Board Description and Adjustments
The switch settings and adjustments in this chapter should be made after your installation and wiring to the operator(s) is
complete.
Whenever any of the programming switches on the circuit board are changed, power must be shut-off, and then
turned back on for the new setting to take effect.
Auto-close timer
(when turned on)
SW 1, switch 2.
Dry relay contacts
(terminals 11-12) can
be set for Normally
Open (NO) or Normally Closed
(NC) operation by placing the
relay shorting bar on the N.O. or
N.C. pins respectively. SW 1,
switches 4 and 5 must be set to
control relay. See next 2 pages
for descriptions.
Auto-Close Timer
AC Module
Adjustment
Single Channel
Loop Detector
Dry Relay
Contact
3-Button Control
Station Jumper
page 23
UL 325 Terminal
and DIP Switches
See pages 24-25
Adjust reversing sensitivity for open and close
directions.
Full counter clockwise for minimum sensitivity,
full clockwise for maximum sensitivity.
See page 20.
Inherent Reverse Sensors
Motor Plug P6
Self-test (when
turned on) SW 2,
switch 1.
CAUTION
Do not
run self-test with the operator
connected to the gate. The drive chain
MUST
be
disconnected before running the self-test. This
feature is designed for bench testing
ONLY
.
Self-Test
Power LED
94
10
9409
1
23
Adjust from 1 second
(full counter-clockwise)
to approximately 23
seconds (full clockwise).
Min
Max
CLOSE
Sensitivity
OPEN
MIN
MAX
Min
Max
Speed
See page 21.
Set the DIP-switches on the circuit
board to the desired setting. See switch
descriptions on next 2 pages.
DIP-Switches
1
ON
2
3
4
5
6
7
8
1
ON
2
3
4
1
ON
2
3
4
1
ON
2
3
4
5
6
7
8
1
ON
2
3
4
5
6
7
8
Limit LEDs
See page 19
8
7
6
5
4
3
Main T
erminal
Input LEDs
See page 22
Gate Tracker
Terminal
See page 23
Limit Sensor
Plug P2
See page 19
Exit Loop Por
t
Reverse Loop Por
t
Sensor Input LEDs
See page 20
LEDs
Indicates that low voltage power is applied to the circuit board.
Input LEDs
should be OFF and will only illuminate
when the input is activated (see page 22).
Limit LEDs
will be on when the respective limit switch is activated.
See page 26.
Dual Channel
Loop Detector
See page 26.
NO
NC
Fire Dept Open
Connect
ONLY
emergency access
controls accessible by authorized
personnel (e.g., fire, police, EMS).
Upon activation, alarm will sound
and the operator will go into a
hard
shutdown
after reaching the open
limit. Operator must be reset to
resume normal operation.
See pages 23, 28-29.