6555-065-A-12-18
17
3.2 DIP-Switch Settings for 4404 Circuit Board
The two DIP-switches located on the circuit board are used to program the operator to operate in various modes and to turn on
or off various operating features. Whenever a switch setting is changed, power to the operator must be turned OFF and then
turned back on for the new setting to take affect. Check and review ALL switch settings prior to applying power to the operator.
See next page for ALL 12 switch definitions and typical settings.
Exit Loop Port
Output
Full Open Input
Warn Before
Operate
The output wired to terminal #4 becomes the output from the loop detector
installed in the
EXIT
loop port. Plug-in loop detector required for “OFF” function.
Normal Setting.
Terminal #4 is a normal full open input for a single gate operator.
Reverses Gate
Switch
Function
Setting
Description
SW 1
OFF
ON
4-OFF
4-OFF
4-ON
4-ON
5-OFF
5-ON
5-OFF
5-ON
Auto-Close
Timer
Relay Activation
and
LED Indicator
Light Activation
2
1
3
4 and 5
7
8
OFF
ON
OFF
ON
Internal alarm will
NOT
sound.
Internal alarm will sound before gate starts and throughout gate’s cycle.
Auto-close timer is OFF. Manual input required to close gate.
Auto-close timer is ON. Adjustable from 1-23 seconds to close gate.
6
Relay activates and LED is ON when the gate is fully open.
Relay activates and LED is ON when the gate is not closed.
Relay activates and LED is ON when the gate is opening and open.
Relay activates and LED is ON when the gate is opening and closing.
Changes the
direction the
operator will
open/close
the gate.
OFF
ON
Normal Setting.
Timer will function normally.
Opening gate will stop and begin to close as soon as all reversing inputs (Reverse
loops, photo sensors) are cleared regardless of the distance the gate has opened.
OFF
ON
Normal Setting.
Input to terminal #6 and/or reverse loops will REVERSE gate
during CLOSE cycle. Shadow loop setting when used, see pages 18 & 26.
DO NOT
use ON setting.
Quick-Close
Timer Override
Opens Counter-Clockwise
using
OFF
setting.
Opens Clockwise
using
ON
setting.
Switch
Function
Setting
Description
SW 2
Spare
4
1
Self-Test
3
Not Used
OFF
ON
Normal Setting.
Normal gate operation.
Self-test mode. Operator
MUST
be disconnected from gate to run self-test.
OFF
Leave in the OFF position.
OFF
Leave in the OFF position.
2
Not Used
OFF
Leave in the OFF position.