RF Baghouse, Models RFWP and RFWPH
44
Cleaning System Assembly and Adjustment
1. With the cleaning arms attached, check the cleaning
arms for free rotation. If rotation is difficult, ensure that
the H-frame is parallel to the tube sheet by measuring
the distance from the H-frame to the tube sheet at all 4
corners - all 4 measurements should be the same. Adjust
the H-frame by moving it in its mounts to the Clean Air
Plenum body.
2. Ensure the air tank is parallel to the tubesheet. If
necessary, use leveling screws in the threaded holes
found on the underside of the H-frame to level the air
tank.
3. Check alignment of the Centering Plate to the pre-drilled
and tapped holes in the tube sheet plate. If the Centering
Plate holes do not align with the tube sheet plate in any
orientation, slide the air tank until it aligns. Check for free
rotation of the cleaning arms and tighten the air tank to
the H-frame.
Note: The Centering Plate allows for movement to help
align the cleaning mechanism. It is able to bolt in
any of four orientations allowing a wide range of
movement.
centering
plate
tube sheet
tube sheet
connecting
plate
cleaning
assembly
shaft
Clean Air Plenum Bottom (Internal View)
Cleaning System Installation