RF Baghouse, Models RFWP and RFWPH
40
Collector Body Assembly for Lower Crane
Capacity
Note: Ensure the crane capacity is rated for the Dirty Air
Plenum plus the Tube Sheet load or the Clean Air Plenum plus
Roof load (whichever is greater) before proceeding with the
below collector body assembly procedure.
Do not lift collector body
assemblies from any flanges found
on the inlet, outlet, or doorways.
Use the provided bolt-on lifting lugs in the
appropriate manner and do not lift more than the
specified weight.
Only lift rings and sections when the load is
balanced.
1. Apply sealant to the top flange of the dirty air plenum
collector body assembly as shown.
2. Lift the tube sheet into the dirty air plenum and slowly
lower the tube sheet into position. Tube sheet stiffeners
will be facing down.
Note: If installing a RF with high inlet, make sure blank
area of tubesheet is aligned with the high inlet
opening of the dirty air plenum.
3. While the tube sheet is still off the flange but the radial
stiffeners are in the dirty air plenum body, rotate the tube
sheet clock-wise (from top) until the stiffeners make
contact with the internal gussets of the dirty air plenum as
shown.
sealant pattern
upper flange
Upper Flange
Sealant Application
bolt hole
Tube Sheet
Installation
internal
gusset
stiffener
tube
sheet
dirty air plenum
tube sheet
Note: Sealant
applied prior
to tube sheet
installation.
Tube Sheet Installation, Model RFWP shown