RF Baghouse, Models RFWP and RFWPH
38
8. Lift the body assembly with the main lifting lugs attached
to the clean air plenum. Position the body over the
involute inlet. For the high body inlet, this assembly
lifts directly onto the hopper flange. Properly orient the
body per the Donaldson-supplied customer drawing or
specification drawing and lower into position.
Note: It is critical that the orientation matches the
specification drawing to ensure there will be NO
interference with ladder and platform locations or
explosion vent locations.
sealant pattern
upper flange
Involute Inlet Flange
Sealant Application
bolt hole
hopper
assembly
involute
inlet
assembly
body
assembly
clean air plenum
lifting lug
Dirty Air Plenum Installation, Model RFWP shown
9. Insert all the 1/2-in hardware and tighten the entire
connecting perimeter.