Page 6
8) TIMER SETTING:
synchronize and
arrange the timers for automatic machine
washing. The switchboard, (see detail
V
fig. 7)
consist of two regulators:
1)
The first timer, which switches the
separator off, control the manure
emptying time of the machine after
feeding pump stop. The setting of
this timer has to be carried out imme-
diately after the first installation, ac-
cording to the time measured neces-
sary for emptying the non homogene-
ous slurry out of the tank.
2)
The second timer comes into operation im-
mediately after the first one and it is useful
for a timed control of the water flow, which
washes the separator. Also for the setting of
this device, For a correct machine washing
take into account the time measured during
the first installation.
If
the feeding pump is
provided with
a level probe,
the two timers’
cycles start automatically after pump stop.
If
the feeding pump is not supplied
a level probe
, the timers’ cycles has to be started man-
ually:
- switch the pump off ;
- put “Manual/Automatic” knob
O fig. 6
on Manual position, with only one shift; then the
cycles programmed by the timers start.
fig. 14
fig. 13
fig. 11
E
F
fig. 12
G
PUMP
SEPARATOR
Summary of Contents for SEPARATOR 2000