Page 21
11. FAILURES AND REMEDIES
The separator’s noise level is very low and, in any case, lower than that usually measured
in a work setting.
Before carrying out any maintenance, regulation or repair operation, stop the
machine (main switch U, fig. 6 must be on position 0) and disconnect supply.
PROBLEMS
CAUSES
REMEDIES
The machine is fed but the
separator do not starts.
- The feeding pump does not
load the medium.
- The medium to separate is
too much dense.
- The feeding line from the
pump to the separator is
plugged.
- Control the correct con-
nection and operation of the
feeding pump.
- Dilute the medium.
- To replace the feeding tube
or clean plugged pipe.
The machine is starts and
stops repeatedly.
- Separator feeding is not
enough.
- Control the feeding pump
and loading increase flow.
The Separator is not
cleaned up well by the
brush.
- The hairs of the brush do not
exit from the grill of the
screen.
- Advance the brush like de-
scribed to paragraph 6.
- If the brush is completely
empty (pointer on the 0°), to
proceed to the substitution .
No dry matter from scrap-
er
The medium is too much liq-
uid.
- Mix the medium in order
to have a thicker product.
The machine suddenly
stops. Re-started works
few seconds only.
- The brush is worn-out.
- Suitably adjust the brush
or replace it.
Summary of Contents for SEPARATOR 2000