E-23
2
Lens Shift Adjustable Range
Lens Shift Adjustable Range for Desktop and Ceiling Mount Application The diagram below shows the location of the image position
in the lens. The lens can be shifted within the shaded area as shown using the normal projection position as a starting point.
Maximum Possible Range for SL-14Z / SL-18Z / SL-25Z / SL-45Z
Parenthesized values for the ceiling mount application
Up: 0.45 V (0.14 V)
Right: 0.28 H (0.17 H)
Down: 0.14 V (0.45 V)
Left: 0.17 H (0.28 H)
(H: width of projected image, V: height of projected image)
For SL-07F
No shift available.
Maximum Possible Range for TL-1ZH / TL-2Z / TL-4Z / TL-08SF
Parenthesized values for the ceiling mount application
For TL-08SF
No shift available.
For TL-1ZH,TL-2Z, 4Z
Up: 0.37 V (0.14 V)
Right: 0.23 H (0.17 H)
Down: 0.14 V (0.37 V)
Left: 0.17 H (0.23 H)
(H: width of projected image, V: height of projected image)
Desktop / Front Vertical
Max. 0.45V
1V
Ceiling / Front Vertical
Max. 0.45V
1V
Normal position
Normal position
Example for Stack
Screen center
(V)
(H)
0.1V
0.28H
0.45V
0.17H
Normal Projection
position
(V)
(H)
0.1V
0.28H
0.45V
0.17H
Normal Projection
position
2. Installation
Note: For TL lenses there is a reduced shift. See ranges above.
Note: Shift limit diagrams above show maximum limits of lens mount not the
specific cababilities of lenses.