![Digital Equipment StorageWorks UltraSCSI DS-BA370 Series User Manual Download Page 79](http://html1.mh-extra.com/html/digital-equipment/storageworks-ultrascsi-ds-ba370-series/storageworks-ultrascsi-ds-ba370-series_user-manual_2498679079.webp)
Environmental Monitoring Unit (EMU)
UltraSCSI RAID Enclosure 3–25
Table 3–7 EMU Fault Code Displays (Continued)
Fault Code, Cause,
Corrective Action
EMU LED Display
Fault Code 0B
Controller fault.
Requires an array controller specific
action (see the array controller
documentation).
1
2
3
4
5
6
7
8
CXO5770A
Fault Code 0C
One or more defective power
supplies.
Observe all power supply status
LEDs. Replace any power supply
with the lower LED O
FF
1
2
3
4
5
6
7
8
CXO5771A
Fault Code 0D
Master enclosure SCSI ID address
incorrect or array controller installed
in expansion enclosure.
1
2
3
4
5
6
7
8
CXO5772A
1. Change the master enclosure SCSI ID to 0 and turn the system O
FF
, and then turn the system
O
N
.
2. Install the array controller in the master enclosure.
Fault Code 0E
EMU memory test failed.
Replace the EMU
1
2
3
4
5
6
7
8
CXO5773A