7–10 UltraSCSI RAID Enclosure
Replacing an SBB
Complete the procedure in Table 7–2 to remove an SBB. When initially
installing SBBs in an enclosure or installing a single SBB, complete the
procedure in Table 7–3.
Table 7–2 Removing an SBB
1. To perform a hot swap go to Step 4.
2. To perform a warm swap, quiesce the SCSI bus.
3. To perform a cold swap, turn off the ac power controller.
4. Press the mounting tabs together to release the SBB.
5. Use both hands and pull the defective SBB out of the shelf.
CXO-4314A-MC
6. Insert the SBB into an electrostatic shipping container.