4
5
3
2
DEC Field Service Instruction
5112 991 12393
7-24
7-25
Part:
Kit Lubrication Felt
Part No.:5112 212 5589x
DEC P/N.:
29-31804-01
REMOVAL
"
Disconnect mains cable
"
Remove all encasing parts (see Part:
Housing
)
"
Remove Encoder Strip (1) (see Part:
Encoder Strip
)
"
Remove operator panel, but leave the interface cable connected (see Part:
Operator Panel
)
Y
M
Remove srew (2) on both sides of the upper guide rail (3)
Y
M
Remove the upper guide rail (3)
Y
M
Exchange the lubrication felt (4). Insert the new felt with flatten
ear (5) towards the operator panel
REASSEMBLING
"
Execute the REMOVAL procedure in reverse sequence