1
2
2
3
4
5
6
Detail A
Detail B
DEC Field Service Instruction
5112 991 10565
7-34
7-35
Part:
Ribbon Gear
Part No.: 5112 292 6384x
DEC P/N.:
FD-W045M-01
REMOVAL
"
Disconnect mains cable
"
Remove all encasing parts (see Part:
Housing
)
"
Remove DEV-40 (see Part:
DEV-40
)
Y
M
Locate the Ribbon Gear (1)
Y
M
Loosen the cable (2) from the cable guide (3)
Y
M
Loosen the spring (4) and remove lever (5)
Y
M
Disconnect the 2 pin motor cable (2) from the motor connector
Y
M
Push the lock tab (6) and remove the Ribbon Gear
REASSEMBLING
"
Execute the REMOVAL procedure in reverse sequence