1
2
Detail A
DEC Field Service Instruction
7-36
7-37
Part:
Stepper Motor 7.5 DEG
Part No.: 5112 292 4106x
(Platen gap control)
DEC P/N.:
FD-W0394-01
REMOVAL
"
Disconnect mains cable
"
Remove all encasing parts (see Part:
Housing
)
"
Remove DEV-40A (see Part:
DEV-40
)
Y
M
Disconnect the four pin motor cables from the motors plug
Y
M
Remove the two screws (1) fixation of the stepper motor
Warning:
Do not loosen the screw (2). This is a factory adjustment;
field adjustment is impossible
Y
M
Remove the stepper motor
REASSEMBLING
"
Execute the REMOVAL procedure in reverse sequence
Note:
Make sure that the cable installation is correct (Detail A)
5112 991 10583