Problem Solving
2–25
b. Plug the output connector on that cable into the test head of the meter.
(Note: The output connector is the smaller of the two connectors on the
cable.)
Figure 2–8:
Measuring the FI Receive Power (Multimode)
LKG–5063–90
I
Normal
connection
FDDI
cable
to bridge
Receive signal
(to bridge)
c. The power level of the receive signal will be displayed on the meter.
Record the value in Table 2–2.
NOTE
If there is no reading when you perform step 5-c, you
could be checking the wrong connector (that is, the input
connector rather than the output). If this occurs, measure
power at the other connector.