1–4
DECbridge 500/600 Series Problem Solving
All DECbridge 500/600 series units contain four logic modules:
•
AP or AP2 (Application Processor) module
•
NI or NI(3) (Network Interface) module
•
FI (Fiber Interface) module with various types of interfaces
•
QM (Queue Manager) module
Table 1–2 shows the four logic modules contained in each bridge model.
NOTE
In this manual, the terms AP and NI are used as general
references to the Application Processor and Network
Interface modules. The terms AP2 and NI(3) are used
only when referring specifically to those two modules.
Table 1–2:
Logic Modules used in the DECbridge 500/600 Series
Model AP Module
NI Module
QM Module
FI Module
500
AP
NI
QM
FI (SAS, MM)
510
AP2
NI
QM
FI (SAS, MM)
518
AP2
NI
QM
FI (SAS, SM)
520
AP2
NI
QM
FI (DAS, MM)
524
AP2
NI
QM
FI (DAS, SM-A, MM-B)
526
AP2
NI
QM
FI (DAS, MM-A, SM-B)
528
AP2
NI
QM
FI (DAS, SM)
600
AP2
NI(3)
QM
FI (Null)
610
AP2
NI(3)
QM
FI (SAS, MM)
618
AP2
NI(3)
QM
FI (SAS, SM)
620
AP2
NI(3)
QM
FI (DAS, MM)
624
AP2
NI(3)
QM
FI (DAS, SM-A, MM-B)
626
AP2
NI(3)
QM
FI (DAS, MM-A, SM-B)
628
AP2
NI(3)
QM
FI (DAS, SM)
Legend: SAS – Single attachment station
DAS – Dual attachment station
MM – Multimode
SM – Single-mode
A and B – DAS interface connectors