Removal and Replacement Procedures
3–3
Table 3–1:
Field-Replaceable Units
FRU
Digital Part Number
Models Used On
AP module
54-19375-01
DECbridge 500 only
AP2 module
54-19375-02
All models except
DECbridge 500
NI module
54-19373-01
All DECbridge 500 series
NI(3) module
54-19409-01
All DECbridge 600 series
FI modules
-SAS multimode
54-19369-01
DECbridge 500, 510, 610
-DAS multimode (A and B)
54-19369-02
DECbridge 520, 620
-SAS single-mode
54-19369-03
DECbridge 518, 618
-DAS single-mode (A)
54-19369-05
DECbridge 524, 624
multimode (B)
-DAS multimode (A)
54-19369-04
DECbridge 526, 626
single-mode (B)
-DAS single-mode (A and B)
54-19369-06
DECbridge 528, 628
-Null
54-19369-09
DECbridge 600
QM module
54-19371-01
All models
Backplane
54-19377-01
All models
Power supply
30-32524-01
All models
Fan assembly
70-27394-01
All models
3.2 Preparing the Bridge for Servicing
Follow these steps before performing any servicing procedures on the bridge.
1. Remove power to the bridge by unplugging the power cord from the ac outlet
and then from the bridge, as shown in Figure 3–2.
2. Disconnect the interface cable(s) from the NI module. Note that the AUI
cable connector locks into place with a slide latch (see Figure 3–2). To re-
move the AUI cable, push the slide latch to the right to unlock the connector.
To remove the ThinWire cable, push in and rotate the connector a quarter
turn.
3. Remove the fiber optic cable(s) from the FI module. If you have a protective
cover available, place it on the fiber optic connector to protect it against dust.