Fig.EE Slots
1 Slot 1
2 Slot 2
3 Fixing lugs
The calculator has two slots for extension modules.
Overview of the possible combinations for the modules for slot 1 and 2
Combinations
●: techn. possible
(●): techn. possible but
not as variant
existing
Module Port 2
no modul
e
M-Bus
RS232
RS485
Impulse
-IN
L-Bu
s (for e
xt
ernal
radio
)
no module
•
(●)
•
(●)
(●)
(●)
M-Bus
• • • •
(●)
•
RS485
•
(●)
(●)
-
(●)
(●)
Impulse-IN
• • • •
-
•
Impulse-OUT
•
•
•
•
•
•
Impulse-IN/-OUT
• • • •
-
•
Analoge Output 4 … 20 mA
•
-
-
-
-
-
L-Bus (for external radio)
•
(●)
(●)
(●)
(●)
-
•
Combination is allowed
-
Combination is not allowed
The modules can be used and combined as shown in the above table. The analogue module occupies
both slots. These modules have no effect on consumption recording and can be fitted retrospectively
without damaging the verification mark.