background image

FDM-4000i Manual V1.0 

 

 

INSTALLATION & CONFIGURATION MANUAL

 

 
 
 

 

FDM-4000i 

4-port SD Digital Modulator with IP 

 
 
 

 

 
 
 
 
 
 

 

 

 

 
 
 
 
 
 

 

 

Summary of Contents for FDM-4000i

Page 1: ...FDM 4000i Manual V1 0 INSTALLATION CONFIGURATION MANUAL FDM 4000i 4 port SD Digital Modulator with IP...

Page 2: ...amming and Setup 8 Connecting to the GUI Interface 8 Encoder Programming and Setup via GUI Interface 9 Overview Page of Fenger Encoder 9 Common Setup 10 RF Setup 11 Encoder Setup 12 IP Streaming Setup...

Page 3: ...y wiring without first disconnecting the unit s power adapter from the device DO NOT connect the power supply to the device if the power cord is damaged DO NOT cut the power cord DO NOT plug the power...

Page 4: ...tor converts Digital Video Broadcasting DVB standard definition video and audio signals to DVB T The unit features programmable channel and network names Adjustable RF output Normal Inverted and C W a...

Page 5: ...o 20dB 1dB step Output Impedance 75 Ohm Output Connector F female IP Output Streaming Method RTP UDP Unicast RTP UDP Multicast Output Connector RJ 45 1Gbps Modulation Video Resolution PAL 720x576 25ft...

Page 6: ...ible UNPACKING and INSPECTION Each unit is shipped factory tested Ensure all items are removed from the container prior to discarding any packing material Thoroughly inspect the unit for shipping dama...

Page 7: ...the audio source to the red white AUDIO L and AUDIO R INPUT jacks IN1 IN4 Use the red and white jacks for audio input or either one for a single input Repeat this step for each audio source connectio...

Page 8: ...oder or connect the Ethernet cable to an Ethernet switch Connect an Ethernet Cable to your PC Static IP address A static IP address must be used on the computer you use to configure the Encoder Refer...

Page 9: ...vice Webpage Overview Page of Fenger Encoder Welcome page showing overview status of the Encoder when fully functioning Step 2 Login Select Common Setup Once the Common Setup Tab is selected you will...

Page 10: ...ave Notes on Changes Changes made to an individual setup tab may require the installer to perform a Local Save AND Upload and Reboot to the device if only making changes to one parameter of the encode...

Page 11: ...dulators in an Installation Please ensure each FDM 4000i Modulator has different settings in the categories below if you are installing 2 or more in an installation Output Channel TS ID Network ID Cha...

Page 12: ...parameters Note There will be an Encoder tab present for each input on the device Step 8 Local Save for each Encoder tab Once all parameters are set you are required to do a Local Save on EACH Encoder...

Page 13: ...y saved before performing Step 11 Step 11 Upload and Reboot Once you have set all the encoder settings and performed a Local Save for each Setup tab Select Upload and Reboot on the IP Streaming page a...

Page 14: ...e s IP address Subnet Mask Gateway Enable Disable DHCP and set Host Name Step 13 Save Network Configuration Save Config Once all parameters are set you are required to select Save Config This function...

Page 15: ...lost Reset to Default Reset all settings back to original factory settings Backup Download all settings of device Upload Upload a saved config file New Password Create and save new password for GUI C...

Page 16: ...vice Saving your configuration files We highly recommend you to save your encoder configuration files Simply Click the Backup button and the config files will be saved to your computer To upload a con...

Page 17: ...oder Video Format Program Num Channel Name Provider Name LCN Aspect Ratio Video Output HDCP Audio Input Audio Output Closed Caption Brightness Contrast Saturation Network Setup Streaming Setup Back to...

Page 18: ...RF data Physical Output Channel Constellation FEC setting OFDM Mode Selection 3 Use the Scroll Up Down button to display IP address Main Menu To access the Main Menu first enter the password by pressi...

Page 19: ...lt Configuration To reset the Encoder Modulator back to the factory default select the Default Configuration Menu Press OK to enter the Default Configuration Menu Using the Up Down button select YES t...

Page 20: ...for each character in the desired Network Name A Network Name can consist up to 16 characters Back to Main Select Back to Main to escape the RF Setup Menu Encoder Setup Menu Select Encoder Press the...

Page 21: ...ress the OK button to set Factory default 128 Sharpness Use the Scroll Up Down button to select Sharpness Press the OK button to enter the Sharpness menu Use the Scroll Up Down button to select the de...

Page 22: ...address begins at 192 168 1 20 Use the Scroll Up Down button to set the Destination IP Address Press the OK button to set Multicast begins at 224 1 1 1 Press the OK button to set Destination IPAddress...

Page 23: ...atic IP Address required Subnet Mask Use the Scroll Up Down button to select Subnet Mask Press the OK button to enter the Subnet Mask menu Use the Scroll Up Down button to enter the Subnet Mask Use th...

Page 24: ...UT VIDEO 2 INPUT VIDEO 3 INPUT VIDEO 4 INPUT DECLARATION OF CONFORMITY Hereby KOSMOSAT SA confirms that the product FDM 4000i SD Digital Modulator with IP conforms to relevant EEC harmonized standards...

Reviews: