4.4.2 Function modules
Pulse input module
The two pulse inputs can be programmed independently of each other with values of 1, 2.5, 10,
25, 100, 250, 1000 or 2500 litres per pulse.
Possible units are all the energy units available in the meter, such as kWh/pulse and GJ/pulse,
but also volume units like l/pulse, m³/pulse or no units.
The input frequency is in the range 0 – 8 Hz, min. pulse duration 10 ms
Input resistance 2.2 MΩ
Terminal voltage 3 V DC
Cable length ≤ 10 m
Electrical isolated
Pulse input 1 is marked “I1 -
┴
” on the module and “IN1” in the display, pulse input 2 “I2 -
┴
” on the
module and “IN2” in the display.
Fig. M
pulse input module
Pulse output module
External power supply Vcc = 3 – 30 V DC
Output current ≤ 20 mA with a residual voltage of ≤ 0.5 V
Open collector (drain)
The module consists of 2 programmable pulse outputs
Output 1:
Frequency: ≤ 4 Hz
Pulse duration: 125 ms ±10 %
Pulse break: ≥ 125 ms -10 %
Output 2:
Frequency ≤ 200 Hz
Pulse duration/pulse break: ~1:1
As a standard the output 1 will give an energy pulse, the output 2 will give a volume pulse (at
calculator for heating or cooling)
At a calculator for heating with cooling tariff the output 1 will give an heating energy impulse and
the output 2 a cooling energy impulse (standard)
The pulse value depends on the digits after the comma of the corresponding display unit. As a
standard the value is always the last digit of the display
The volume pulse value is decadal value programmable
Floating contact (electrically isolated)
The lifetime of the battery which is mounted on the module is 12 years.