Seite 31 von
71
Fig. S
Seals
1 Seals
2 Cable bushings
6.1
Installation
CAUTION
If medium temperature is lower than ambient temperature!
Risk of damage to calculator due to condensation.
Use the sealed variant of a connected flow sensor
Remove calculator from the flow sensor (Fig. U, page 36).
NOTE
Install the calculator in an accessible position for service and operating personnel.
It is recommended that stop valves be fitted before and after the calculator
connected to the flow sensor to simplify removing the calculator.
1
1
2