3.5.1 Battery
A 3.6 V DC lithium battery is fitted in the standard version. The battery is not to be charged or short-
circuited. Ambient temperatures below 40 °C extend the life of the battery.
DANGER
There is a risk of explosion if the battery is replaced with the wrong type of
battery.
3.5.2 Overview of the measuring rates
The following table shows the lifetime of the batteries depending on the standard measuring rates.
Customer versions can differ from the standard measuring rates in the measuring rate and battery
lifetime.
DM Standard
(av. Amb.Temp.: 22°C)
Battery‐
Lifetime
[anno]
radio
Interval
[s]
measuring rate
(independent from
radio) [s]
A‐Cell up to
flow
Temperature
no radio/ no Module
12
‐
1
16
868MHz
11
180
434MHz
11
180
Quick mode
6,5
12
D‐Cell up to
no radio/ no Module
16
‐
1
4
868MHz
16
12
434MHz
16
12
mains
no radio/ no Module
no limit
‐
8Hz.
2
868MHz
no limit
12
434MHz
no limit
12
1
:
for „moderate“ ambient temperature. Temperature above 35°C reduces the lifetime.
The temperature for storage of the calculator in a warehouse shall be less than 35°C.
The calculation of flow and volume is done every 2 seconds.
After that the display is updated every 2 seconds.
To save energy the calculator tries to do all its operations like metering, calculation and updating
the
display at the same time.
Summary of Contents for SCYLAR INT 8
Page 19: ...Seite 19 von 71 4 Technical data 4 1 Dimensions Fig F Dimensions ...
Page 67: ...Seite 67 von 71 13 Declaration of conformity ...
Page 68: ...Seite 68 von 71 ...
Page 69: ...Seite 69 von 71 ...
Page 70: ...Seite 70 von 71 ...
Page 71: ...Seite 71 von 71 ...