E07
Spindle is disabled after a Reject report.
If the Stop on bad report box in the STATION menu is activated, then the tool will be disabled.
To enable it, it is necessary to activate the Failure acknowledge input on the I/O port.
e09
CVINET FIFO is full.
The cycle can start but there is no free memory space left in the FIFO.
Problem with the Ethernet connection or configuration may be the cause.
E09
CVINET FIFO is full.
The cycle can not start because the Locking on when FIFO is full option is validated and there is no
free memory space left in the FIFO.
Problem with the Ethernet connection or configuration may be the cause.
E10
Report acknowledgement.
The tool does not start when this error is present.
If the "Report acknowledgement" parameter of the station menu is activated, the cycle start is
inhibited.
To release the tool start, send a "rising edge" to the "Request Report" signal on the input port.
e12
ToolsNet FIFO is full.
The cycle can start but there is no free memory space left in the FIFO.
Problem with the Ethernet connection or configuration may be the cause.
E12
ToolsNet FIFO is full.
The cycle can not start because the Locking on when FIFO is full option is validated and there is no
free memory space left in the FIFO.
Problem with the Ethernet connection or configuration may be the cause.