CVIL II
Select the relevant action:
Parameter
Comment
Unused
The option is disabled.
Stop cycle
As soon as one of the torque or angle
parameters is out of tolerances at the
end of one of the phases, the cycle
stops at the end of this phase.
Run reverse
The cycle stops under the same
circumstances as in the Stop Cycle
option, then the tool un-tightens with the
programmed number of rotations.
● Number of rotations:
- 1 – 9
● Run reverse speed:
- 50% by default.
In the Pulse mode, the "Run
reverse speed" is set to 30%
by default.
● Thread:
- Right / Left.
Rv speed
Run reverse speed associated with an
action on NOK per cycle or per phase.
Thread
Right / Left.
Time
Time to run reverse.
When an action on NOK phase has been
programmed, it will be processed as a priority
with respect to the action on NOK of the cycle.
7.3.3.2 - Parameters cycle (in Normal mode)
2
3
4
1
Legend
1 Nb of cycles OK
2 Report threshold value
3 Control current strategy
4 Results strategy
Select the relevant action:
Parameter
Comment
Nb cycles OK
Number of correct cycles to activate
the NCYOK output.
Rep. Thr
Torque threshold value to allow to
send a cycle report.
Result./
Cycle: Report is generated when
cycle is completed.
Phase: Report is generated any time
a phase is completed.
Control I
(●) Enabled (Yes ): Torque and
current are evaluated to generate
cycle report.
( ) Disabled (No): Only torque is
evaluated to generate cycle
report.