01/2018
56 / 80
6159933780
Issue no: 09
CVIL II
10 - PRINTING FORMAT FOR
TIGHTENING RESULTS
10.1 - PC2 format
Char
number Designation
1
char. <CR>
2
range or cycle number
2
fastener number
3
«T=+»
5
torque in 1/10 of Nm
1
<LF>
1
" "
1
<CR>
2
range or cycle number
2
fastener number
3
«A=+»
5
angle in 1/10 of degree
1
<LF>
1
" "
1
<CR>
2
range or cycle number
2
fastener number
3
«TR=+»
5
torque rate in 1/1000 Nm/dg
1
<LF>
1
" "
Example of result:
<CR>0109T=+00400<LF> <CR>0109A=+01200<LF>
<CR>00580<LF>
The last result in the list ends with <LF><LF> instead of
<LF>""
10.2 - PC3 format
Char
number Designation
1
char. A (frame type)
3
station number (1 to 250)
3
port number (1 to 32)
1
configuration (A to O correspond to
configurations 1 to 15)
1
Z (system identifier)
1
char. A (frame type)
1
report code (see chart below)
6
date (year, month, day)
6
time (hour, minute, second)
8
torque
5
angle
1
<CR>
1
Checksum (modulo sum 256 of the previous
characters) not calculated for the moment
1
<LF>
The last result in the list ends with <LF><LF> instead of
<LF>
Report code: ASCII code 0100 :
X
X
X
X
1
2
3
4
Legend
1 1 = max. angle
2 1 = min. angle
3 1 = max. torque
4 1 = min. torque
According to the various combinations, the following
characters will be obtained:
@
accept torque accept angle If "NOK:SCY=0"
is set to "Yes"
O
accept torque accept angle If "NOK:SCY=0"
is set to "No"
A
min. torque
accept angle
B
max. torque
accept angle
D
accept torque min. angle
E
min. torque
min. angle
F
max. torque
min. angle
H
accept torque max. angle
I
min. torque
max. angle
J
max. torque
max. angle
0x00
on servodrive fault
or spindle belonging to reject group
or cycle start drop
or cycle not completed for spindle
or transducer fault
Example of result:
<CS><LF>