Issue no: 09
CVIL II
Parameter Comment
Power
1 - 100%
No result for this phase.
7.3.5.2 - Run Down Speed Phase
(Normal mode and Pulse mode)
Parameter Comment
Max.time
Maximum phase running time: 0.01 - 99 s.
Int.time
Time programmed between this phase
and the next one: 0 - 20 s.
Target T
Target torque: 0 Nm to maximum value of
the spindle (screw approach torque).
Other...
See Motor parameters.
No result for this phase.
7.3.5.3 - Final Speed Phase
(Normal mode and Pulse mode)
Parameter
Comment
Max.time
Maximum phase running time:
0.01 - 99 s.
Int.time
Time programmed between this phase
and the next one: 0 - 20 s.
Tightening
strategy
Torque / Angle.
Angle + Torque.
Stall torque.
Seating.
Post-seating.
Min T
Minimum torque: 0 Nm to maximum
value of the spindle.
Target T
Target torque: 0 Nm to maximum value
of the spindle.
Max T
Maximum torque: 0 Nm to maximum
value of the spindle.
Threshol
Angle threshold: 0 Nm to maximum
value of the spindle.
Latch angle
The angle reading can be stopped in
each individual phase in a cycle. There
are 3 different settings:
● Threshold (by default): the
controller starts measuring the
angle when the torque is above
the torque threshold, even after the
motor stop.
● Motor stop: the angle is not read
anymore after the motor stop.
● None: no latch angle.
Min A
Minimum angle: 0 - 9,999°.
Max A
Maximum angle: 0 - 9,999°.
Safety A
Safety angle: 0 - 9,999°.