01/2018
46 / 80
6159933780
Issue no: 09
CVIL II
8 - MAINTENANCE
This section helps the maintenance operator to:
● Check that the cont tool assembly operates
correctly.
● Know the number of cycles run.
● Tune the system manually or automatically.
● Adjust the contrast of the display, update controller
date, select the language and program an access
code.
● Change the memory batterie.
● Backup and restore the controller.
8.1 - MAINTENANCE menu
8.1.1 - TEST menu
8.1.1.1 - START SPINDLE menu
The START SPINDLE menu allows you to check the
correct operation of the tool.
● Select the speed and rotation direction (Directi
reverser for a hand held tool or in the menu for a
fixed tool) then press the trigger for a hand held tool
of ER type or press the On button for a fixed tool of
EME or EML type.
● Select Reset to reset the display.
● Select Ventil. to start the fan and check its working
order.
8.1.1.2 - INPUT / OUTPUT menu
2
4
1
3
Legend
1 Input no 1
2 Input no 8
3 Output no 1
4 Output no 8
The INPUT/OUTPUT menu allows you to check the
status of inputs and to test the outputs.
Testing the outputs:
● The cursor blinks on output 1 (3).
● Press to move the cursor.
● Press
to validate the box or not.
● The selected output is or is not enabled.
● Then it is possible to check the efficiency of the status
change of this output on the corresponding input, for
example on the PLC.