01/2018
19 / 80
6159933780
Issue no: 09
CVIL II
2
Legend
2 Max speed limit
● Enter max speed limit (if required).
● Press
to validate.
3
Legend
3 Final torque
● Enter final torque.
● Press
to validate.
4
Legend
4 Learning
● Perform 3 tightening operations.
● Press
to validate.
7.3 - CYCLES menu
7.3.1 - Introduction
The CYCLES menu allows you to change or create the
programming of the cycles.
A tightening cycle consists of a sequence of phases run
consecutively.
Each phase is defined by main parameters and
tightening instructions according to the selected type of
tightening and motor settings.
Various phases available
in a cycle
Letter Normal
mode
Pulse
mode
Search sequence
S
X
X
Run down speed
D
X
X
Final speed
F
X
X
Run reverse
R
X
X
Act. on NOK
V
X
X
Jump
J
X
X
Prevail. Torque
P
X
X
Synchr. waiting
W
X
X
Empty phase
X
X
The procedure for programming the cycle can be broken
down as follows:
● Selecting the station mode: Normal / Pulse.
Refer to chapter 7.7.1.
● Selecting the cycle.
● Selecting and sequencing the phases.
● Programming the parameters of each phase.
● Selecting an Action on NOK or not.
● Entering a comment.
● Programming the Number of cycles OK.