01/2018
44 / 80
6159933780
Issue no: 09
CVIL II
7.9 - CONTROLLER menu
Parameter
Comments
Comment
Possibility to add a comment up to 15 characters to identify the controller.
Fst
Possibility to add a comment or figures up to 3 characters to identify the fastener.
Ergo-stop
Displayed in Normal mode only.
Activates or not the ergo-stop function at the end of the tightening operation. This reduces the
reaction shocks at the end of the tightening and is recommended for portable tools.
K.nload
Nominal load coefficient for use of external torque multiplier. Update torque calibration.
K.gear
Gear ratio coefficient for use of an external torque multiplier. Update angle calibration.
K.torsion
Torsion coefficient used in control angle strategies to compensate the mechanical torsion of the
installation.
2nd trigg