Chapter 4 Parameters
|
VFD-L-I Series
Revision July 2009, SW V1.1
4-35
05-04
PLC Forward/Reverse Motion
Unit: 1
Settings
0 to 5
Factory Setting: 0
This parameter controls the direction of motion for the Multi-Step Speed Pr.05-00 to Pr.05-03
and the Master Frequency.
NOTE
The equivalent 8-bit number is used to program the forward/reverse motion. The binary notation for
the 8-bit number must be translated into decimal notation and then be entered.
1
2
3
0=F or w ard
1=R evers e
Di re ctio n o f 1st
P r.05 -0 0
sp ee d fo r
Di re ctio n o f 2n d
P r.05 -0 1
sp ee d fo r
Di re ctio n o f 3r d
P r.05 -0 2
sp ee d fo r
0
Di re ctor of Ma ster Fre qu en cy du ri ng PL C
05-05
Time Duration of Zero Step Speed (corresponding parameter 02-00)
Unit: 1
05-06
Time Duration of 1st Step Speed (corresponding parameter 05-00)
Unit: 1
05-07
Time Duration of 2nd Step Speed (corresponding parameter 05-01)
Unit: 1
05-08
Time Duration of 3rd Step Speed (corresponding parameter 05-02)
Unit: 1
Settings
0 to 65500 Factory Setting: 0
Pr.05-05 to Pr.05-08 correspond to operation time of each multi-step speed defined by
parameters 02-00 and 05-00 to 05-02. The maximum value of these parameters is 65500 sec.,
and it’s displayed as 65.5.
NOTE
If a parameter is set to “0” (0 Sec), the corresponding step will be skipped. That means though VFD-
L-I series provides 4 step speeds, user can set the unnecessary step speed to 0 by his application.