Chapter 4 Parameters
|
Revision May 2008, ME14, SW V3.04
4-25
Actual Acceleration/Deceleration Time=
Acceleration/Deceleration Time x(Master Freq.-Min.Output Freq.)
Max. Output Freq.
Frequency
Max.
Output
Freq.
Pr.10
or
Pr. 12
Pr.11
or
Pr. 13
Time
Deceleration Time
Acceleration Time
Pr.14
Acceleration S-Curve
Settings 00 to 07
Factory Setting: 00
This parameter is used whenever the motor load needs to be accelerated or decelerated
smoothly. The desired accel/decel effect is selectable from 0 to 7, in which the larger the
number, the greater the effect achieved. If the default value of Pr.111 Deceleration S Curve is
unchanged (“0”), then Pr.14 sets both acceleration and deceleration S-Curves. If Pr.111 is set
to any value other than “0”, then Pr.14 will set the acceleration S-Curve and Pr.111 will set the
deceleration S-Curve.
Freq.
Acceleration/Deceleration characteristics
(1), (2) Disabling S curve
(3), (4) Enabling S curve
Pr.15
Jog Accel / Decel Time
Unit: 0.1 or 0.01 sec
Settings 0.1 to 600.0 sec or 0.01 to 600.0 sec
Factory Setting: 1.0 sec
This parameter sets the acceleration or deceleration time for Jog operation.
Pr.16
Jog Frequency
Unit: 0.1 Hz
Settings 0.00 to 400.0 Hz
Factory Setting: 6.00 Hz
Summary of Contents for VFD-M Series
Page 1: ......
Page 2: ......
Page 3: ......
Page 12: ...Chapter 1 Introduction Revision May 2008 ME14 SW V3 04 1 3 1 1 4 External Parts and Labels ...
Page 17: ...Chapter 1 Introduction 1 8 Revision May 2008 ME14 SW V3 04 This page intentionally left blank ...
Page 21: ...Chapter 2 Installation and Wiring 2 4 Revision May 2008 ME14 SW V3 04 Good Not allowed ...
Page 121: ...Chapter 4 Parameters 4 86 Revision May 2008 ME14 SW V3 04 This page intentionally left blank ...
Page 149: ...Appendix B Accessories B 4 Revision May 2008 ME14 SW V3 04 ...