Pr.97
Preset Count Down Completion
Settings 00 to 9999
Factory Setting: 00
This parameter sets a preliminary count value for the internal counter. Counter is incremented
by a low-to-high transition on one of the programmed Multi-Function Input Terminals: M1 or
M2 (see Pr.44 or Pr.45, setting 14). Count starts at 01. Upon completion the selected Multi-
Function Output Terminal will close. Preliminary Count could be used to initiate an external
event before the
“
terminal count
”
is reached. (See Pr.38, 39, 40, 41, 42, 45, and 46 for further
details.)
Pr.98
Total Time Count from Power On (Days)
Settings 00 to 65535 days
Read Only
Pr.99
Total Time Count from Power On (Minutes)
Settings 00 to 1440 minutes
Read Only
Pr.100
Software Version
Read Only
This parameter shows the software version for the AC motor drive.
Pr.101
Auto Acceleration/Deceleration
Factory Setting: 00
Settings
00
Linear
acceleration/deceleration
01 Auto acceleration, linear deceleration
02 Linear acceleration, auto deceleration
03
Auto
acceleration/deceleration
04 Linear Accel/Decel Stall Prevention during Deceleration
(Please refer to Accel/Decel time setting at parameter Pr.10-Pr.13)
When this parameter is set to 03, the AC drive will accel/decel in the fastest and smoothest
possible way by automatically adjusting the accel /decel time.
This parameter provides five modes to choose:
00
Linear acceleration and deceleration (operation by Pr.10, Pr.11, or Pr.12, Pr.13
acceleration/deceleration time)
01
Automatic acceleration, linear deceleration (Operation by automatic acceleration,
Pr.11 or Pr.13 deceleration time).
Summary of Contents for VFD-M Series
Page 1: ......
Page 2: ......
Page 3: ......
Page 12: ...Chapter 1 Introduction Revision May 2008 ME14 SW V3 04 1 3 1 1 4 External Parts and Labels ...
Page 17: ...Chapter 1 Introduction 1 8 Revision May 2008 ME14 SW V3 04 This page intentionally left blank ...
Page 21: ...Chapter 2 Installation and Wiring 2 4 Revision May 2008 ME14 SW V3 04 Good Not allowed ...
Page 121: ...Chapter 4 Parameters 4 86 Revision May 2008 ME14 SW V3 04 This page intentionally left blank ...
Page 149: ...Appendix B Accessories B 4 Revision May 2008 ME14 SW V3 04 ...