Identifying the Failed Cooling Fan Module
To determine which cooling fan module failed, use Dell Storage Manager.
1.
Click the
Hardware
tab.
2.
In the
Hardware
tab navigation pane, select and expand the Storage Center.
3.
In the
Hardware Alerts
area, find the hardware alert that identifies the expansion enclosure with the failed cooling fan module.
Figure 37. Hardware Alert Identifying the Expansion Enclosure with the Failed Cooling Fan
4.
In the
Hardware
tab navigation pane, expand the expansion enclosure identified in the previous step.
5.
Select
Cooling Fans
.
The status of each cooling fan module is displayed in the
Cooling Fans
tab.
6.
Select the failed cooling fan.
The location of the failed cooling fan module is displayed in the
Fan View
tab.
Figure 38. Rear View of the Expansion Enclosure Showing the Failed Cooling Fan Module
Remove a Cooling Fan Module
Use this procedure to remove a cooling fan module.
Prerequisites
1.
Use SupportAssist to send diagnostic data to Dell Technical Support.
2.
Change the operation mode of the Storage Center to Maintenance.
Replacing SCv360 Expansion Enclosure Components
39