Chapter 3 Connect the Back End
86
Storage Center SC8000 Controller Deployment Guide
Single Controller, Four Enclosures, Single Chain
This
illustration
shows
a
single
SC8000
controller
cabled
to
four
SAS
enclosures.
Figure 79. Single SC8000 Controller, Single 6 Gb Chain
Path
Connections
Chain
1:
A
Side
1 Controller:
slot
6,
port
1
→
Enclosure
1:
top
SBB,
port
C.
2 Enclosure
1:
top
SBB,
port
B
→
Enclosure
2:
top
SBB,
port A.
3 Enclosure
2:
top
SBB,
port
B
→
Enclosure
3:
top
SBB,
port A.
4 Enclosure
3:
top
SBB,
port
B
→
Enclosure
4:
top
SBB,
port A.
Chain
1:
B
Side
1 Enclosure
1:
bottom
SBB,
port
A
→
Enclosure
2:
bottom
SBB,
port
B.
2 Enclosure
2:
bottom
SBB,
port
A
→
Enclosure
3:
bottom
SBB,
port
B.
3 Enclosure
3:
bottom
SBB,
port
A
→
Enclosure
4:
bottom
SBB,
port
B.
4 Enclosure
4:
bottom
SBB,
port
C
→
Controller:
slot
6,
port
3.
Enclosure 1
Enclosure 2
Enclosure 3
Enclosure 4
Controller
4
3
2
1