![Dell SC8000 Deployment Manual Download Page 122](http://html.mh-extra.com/html/dell/sc8000/sc8000_deployment-manual_79830122.webp)
Chapter 4 Connect the Front End
112
Storage Center SC8000 Controller Deployment Guide
Figure 96. Dual-controller with Single-Network iSCSI in Legacy Mode
Legacy Mode with Dual-Network iSCSI
Use
two
networks
with
legacy
mode
to
prevent
a
switch
failure
or
controller
failure
from
causing
an
outage.
In
this
configuration,
four
fault
domains
are
spread
across
both
controllers.
Each
fault
domain
contains
sets
of
primary
and
reserve
paths
(P1
‐
R1,
P2
‐
R2,
P3
‐
R3,
and
P4
‐
R4).
To
provide
redundancy,
the
primary
port
and
the
corresponding
reserve
port
in
a
fault
domain
must
connect
to
the
same
network.
When
MPIO
is
configured
on
the
iSCSI
servers,
the
primary
paths
provide
redundancy
for
a
single
port
or
cable
failure.
The
reserved
paths
provide
redundancy
for
single
controller
failure.
Prerequisites
Each
controller
must
have
two
available
iSCSI
front
‐
end
ports
for
each
Ethernet
switch.
Steps
1
Connect
each
iSCSI
server
to
both
Ethernet
switches.
2
Connect
fault
domain
1
(shown
in
orange)
to
switch
1.
Primary
port
P1
:
Controller
A,
slot
3,
port
1
→
Switch
1
Reserved
port
R1
:
Controller
B,
slot
3,
port
1
→
Switch
1
Ethernet Switch 1
iSCSI Network 1
Server
Controller B
Controller A
P1
P2
R1
R2
4
3
2 1
4
3
2 1
1 2
1 2
2 1
2 1