Chapter 4 Connect the Front End
98
Storage Center SC8000 Controller Deployment Guide
See Also
Example Virtual Port Mode Configuration
The
following
figure
shows
a
dual
‐
controller
Storage
Center
in
virtual
port
mode
connected
to
a
Fibre
Channel
server
with
a
single
fault
domain.
All
ports
belong
to
a
single
fault
domain
because
they
are
connected
to
the
same
FC
switch.
Figure 88. Virtual Ports Example with FC
The
following
table
summarizes
the
failover
behaviors
for
this
configuration.
Multipathing
If
multiple
active
paths
are
available
to
a
server,
the
server
must
be
configured
for
MPIO
to
use
more
than
one
path
simultaneously.
iSCSI
networks
• NAT
must
be
disabled
for
iSCSI
replication
traffic.
• CHAP
authentication
must
be
disabled.
Fibre
Channel
fabrics
• The
FC
topology
must
be
switched
fabric.
Point
‐
to
‐
point
and
arbitrated
loop
topologies
are
not
supported.
• FC
switches
must
be
zoned
to
meet
the
virtual
port
mode
zoning
requirements.
• FC
switches
must
support
N_Port
ID
Virtualization
(NPIV).
• Persistent
FCID
must
be
disabled
on
FC
switches.
Note:
AIX
servers
are
not
supported.
Note:
To
use
both
primary
paths
simultaneously,
the
server
must
be
configured
to
use
MPIO.
Scenario
Failover Behavior
Normal
operating
conditions All
ports
are
active
and
pass
IO.
Controller
A
fails
Virtual
ports
on
controller
A
fail
over
by
moving
to
physical
ports
on
controller
B.
Controller
B
fails
Virtual
ports
on
controller
B
fail
over
by
moving
to
physical
ports
on
controller
A.
A
single
port
fails
The
virtual
port
associated
with
the
failed
physical
port
moves
to
another
physical
port
in
the
fault
domain.
Requirement
Description
FC Switch
Server
Controller A
Controller B
Active Ports