![Dell SC8000 Deployment Manual Download Page 103](http://html.mh-extra.com/html/dell/sc8000/sc8000_deployment-manual_79830103.webp)
Label the Back-End Cables
Dell Compellent
93
Label the Back-End Cables
Label
the
back
‐
end
cables
that
connect
controllers
to
enclosures
to
indicate
the
chain
number
and
side
(A
or
B).
Pre
‐
made
labels
are
provided
for
SC200/220
enclosures.
Labels
are
not
provided
for
EN
‐
SASx6x12/24
enclosures,
so
labels
must
be
created
manually
for
cables
that
connect
to
those
enclosures.
Prerequisites
If
the
Storage
Center
has
EN
‐
SASx6x12/24
enclosures,
you
must
have
a
label
maker,
or
four
blank
labels
and
a
writing
utensil.
Steps
1
Locate
or
create
labels
for
the
back
‐
end
cables.
EN
‐
SASx6x12/24
enclosures
:
Create
labels
that
label
the
purpose
(Backend),
chain
number,
and
side
(A
or
B).
Example
:
Backend
1A
SC200/220
enclosures
:
Locate
the
back
‐
end
cable
labels
that
shipped
with
the
enclosures.
The
pre
‐
made
labels
include
the
purpose
(Backend),
chain
number,
and
side
(A
or
B).
Figure 85. SC200/220 Back-End Cable Label
Note:
Cables
that
connect
one
enclosure
to
another
do
not
need
to
be