Complete the Startup Wizard
Dell Compellent
155
2
Create
the
required
fault
domains.
For
a
dual
‐
controller
Storage
Center,
create
a
fault
domain
for
each
pair
of
redundant
FC
ports.
For
a
single
‐
controller
Storage
Center,
create
a
single
fault
domain
for
all
FC
ports.
a
Click
Edit
Fault
Domains
.
The
wizard
displays
a
list
of
the
currently
defined
fault
domains.
b
Click
Create
Fault
Domain
.
A
dialog
box
appears.
c
In
the
Name
field,
type
a
name
for
the
fault
domain.
d
From
the
Type
drop
‐
down
menu,
select
FC
.
e
(Optional)
In
the
Notes
field,
type
a
description
of
the
fault
domain.
f
Click
Continue
.
The
dialog
box
displays
a
summary.
g
Click
Create
Now
to
create
the
fault
domain.
h
Repeat
steps
as
needed
to
create
additional
fault
domains.
i
When
you
are
finished
creating
fault
domains,
click
Return
.
The
FC
tab
appears.
3
Configure
each
back
‐
end
FC
port.
a
Set
the
Purpose
field
to
Back
End
.
b
Confirm
that
the
Fault
Domain
field
is
set
to
<none>
.
c
(Optional)
Type
a
descriptive
name
in
the
User
Alias
field.
4
Configure
each
front
‐
end
FC
port.
a
Set
the
Purpose
field
to
Front
End
Primary
or
Front
End
Reserved
as
appropriate.
b
Set
the
Fault
Domain
field
to
the
appropriate
fault
domain
that
you
created.
c
(Optional)
Type
a
descriptive
name
in
the
User
Alias
field.
5
Configure
each
port
that
is
unused
or
used
for
IPC
between
controllers.
a
Set
the
Purpose
field
to
Unknown
.
b
Confirm
that
the
Fault
Domain
field
is
set
to
<none>
.
c
(Optional)
Type
a
descriptive
name
in
the
User
Alias
field.