![Dell SC8000 Deployment Manual Download Page 199](http://html.mh-extra.com/html/dell/sc8000/sc8000_deployment-manual_79830199.webp)
Adding SC200/220 Enclosures
Dell Compellent
189
8
Disconnect
the
B
‐
side
cables
from
the
controllers
as
shown
in
Controller
A:
slot
6
port
3.
Controller
B,
slot
6
port
1.
IO
continues
through
the
A
‐
side
cables.
9
Move
the
cable
from
Enclosure
2:
bottom,
port
B
→
Enclosure
4:
bottom,
port B.
10
Use
new
cables
to
connect
the
new
enclosures
to
the
existing
enclosures
(B
side):
Enclosure
2:
bottom,
port
B
→
Enclosure
3:
bottom,
port
A.
Enclosure
3:
bottom
port
B
→
to
Enclosure
4:
bottom
port
A.
Enclosures
3
and
4
are
now
part
of
the
B
‐
side
chain
and
can
be
connected
to
Controllers
A
and
B.
Figure 120. Connect SC200/220 Enclosures to B Side
Disconnect B side
Connect
Enclosures
(B side)
Move Cable from
Enclosure 2
Enclosure 1
Enclosure 2
Enclosure 3
Enclosure 4
Controller A
Controller B
Add cable