100010018
The storage capacity of your SSDs in the cluster is approaching capacity.
Administrator action
Reduce the amount of data that is stored on the SSD or contact your sales representative to discuss your capacity needs.
100010019
A serially-attached SCSI (SAS) controller logged an error or a change in the disk subsystem.
Description
When disk drives go into error recovery, they hold the PHY connection open. The LSI 2008 SAS controllers can time out on
that open connection. When the LSI controller reaches its timeout threshold, the SAS connection is reset, which causes the SAS
BER error messages and event notifications.
Administrator action
Verify that the node firmware and drive firmware are up to date. The latest firmware packages can be downloaded from the
site.
If the event persists, gather logs, and then contact Technical Support for additional troubleshooting. For instructions on how to
gather cluster logs, see
.
100010020
A serially-attached SCSI (SAS) controller logged an error or a change in the disk subsystem.
Description
When disk drives go into error recovery, they hold the PHY connection open. The LSI 2008 SAS controllers can time out on
that open connection. When the LSI controller reaches its timeout threshold, the SAS connection is reset, which causes the SAS
BER error messages and event notifications.
Administrator action
Verify that the node firmware and drive firmware are up to date. The latest firmware packages can be downloaded from the
site.
If the event persists, gather logs, and then contact Technical Support for additional troubleshooting. For instructions on how to
gather cluster logs, see
.
40