100010024
A configuration file is missing for the identified drive model.
Administrator action
Gather logs, and then contact Technical Support for additional troubleshooting. For instructions on how to gather cluster logs,
see
.
100010025
A SMART status threshold for the identified bay has been exceeded.
Administrator action
Troubleshooting is required to determine if a hardware component must be replaced.
Gather logs, and then contact Technical Support for additional troubleshooting. For instructions on how to gather cluster logs,
see
.
100010026
An encrypted drive is in an insecure state
Administrator action
1. Smartfail the specified drive. Do not remove the drive from the node.
2. Reinstall the smartfailed drive by running the following command:
isi devices drive format <bay> --node-lnn <integer>
If the event persists, gather logs, and then contact Technical Support for additional troubleshooting. For instructions on how to
gather cluster logs, see
.
100010027
The drive subsystem determined that the drive firmware version on a drive is incorrect.
Administrator action
Verify that the drive support package and drive firmware are up to date.
You can download the latest drive support packages and drive firmware from the
site.
If the event persists, gather logs, and then contact Technical Support for additional troubleshooting. For instructions on how to
gather cluster logs, see
.
42
Software events