900010002
The node needs a battery replacement.
Administrator action
View the status of each battery by running the following command from any node in the cluster:
isi_for_array -s 'isi_hw_status -bg | grep Battery'
●
For legacy hardware follow the instructions to initiate a battery test by following the instructions in
Understanding Isilon
node battery testing
,
.
●
For NL410, X210, S210, X410, and HD400 nodes, contact Dell EMC PowerScale Technical Support for troubleshooting.
900010003
There is an issue with the NVRAM card.
Administrator action
Reboot the node. If the event clears and does not recur, no other action is required.
If the event persists, gather logs, and then contact Technical Support for additional troubleshooting. For instructions on how to
gather cluster logs, see
.
900010004
A sensor has detected that the node chassis is open.
Description
This event typically appears when maintenance is being performed on the inside of the node, while the node is powered on. Or,
this event might appear if one of the NVRAM battery trays were pulled out.
Administrator action
1. Make sure that the battery tray is properly inserted.
2. If the node chassis is open, close the chassis.
If the event persists, gather logs, and then contact Technical Support for additional troubleshooting. For instructions on how to
gather cluster logs, see
.
900010005
A memory, PCI, or PCIe bus error has occurred in the node.
Administrator action
Troubleshooting is required to determine if a hardware component must be replaced.
Gather logs, and then contact Technical Support for additional troubleshooting. For instructions on how to gather cluster logs,
see
.
118
Hardware events